Where RL is the inductance of the winding = 2×3.14xpXL, where P is the power frequency, that is to say, the higher the frequency is, the greater the inductive reactance will be, and When the frequency is high, few windings will also have a great inductive reactance and will not short circuit. So the higher the frequency is, the fewer turns will be.
Transformer windings are inductive devices. When the magnetic core is fixed, its inductance L is proportional to the number of turns. When the magnetic core and winding are fixed, its inductance is fixed