Control transformer
The control transformer is mainly suitable for AC 50 Hz (or 60 Hz), voltage 1000 V and below, and can work continuously for a long time under rated load. Usually used in machine tools or mechanical equipment as electrical control lighting and indicator power supply.
Description
The control transformer is mainly suitable for AC 50 Hz (or 60 Hz), voltage 1000 V and below, and can work continuously for a long time under rated load. Usually used in machine tools or mechanical equipment as electrical control lighting and indicator power supply.
In the low-voltage distribution system, the control transformer is often used in the control system. It is actually a step-down transformer with a variety of output voltages, and can also be used as a power supply for low-voltage lighting, signal lights, and indicator lights.
The control transformer has the characteristics of small size, safe and reliable wiring, high protection level, good performance, and can work effectively in the rated load for a long time.
Working principle
The control transformer works on the principle of electromagnetic induction. The transformer has two sets of coils. Primary and secondary coils. The secondary coil is outside the primary coil. When the primary coil is connected with alternating current, the transformer core produces an alternating magnetic field, and the secondary coil produces induced electromotive force. The turn ratio of the transformer coil is equal to the voltage ratio
- Efficiency ≥ 95%
- Insulation resistance ≥ 20m Ω
- Overload capacity twice the rated current for one minute
- No breakdown and flashover is found in the power frequency sinusoidal voltage of 2000V for one minute
- Insulation class B (130 ℃), f (155 ℃), H (180 ℃)
- Noise < 55dB
- The ambient temperature is – 15 ℃ – + 40 ℃, and the maximum monthly average temperature is not more than 35 ℃
- Installation altitude < 1000M
- The ambient air humidity is from – 5 ℃ to + 40 ℃, and the average value within 24 hours does not exceed + 35 ℃;
- The altitude of the installation site shall not exceed 2000m;
- When the ambient air humidity is + 40 ℃, the atmospheric relative humidity is not more than 50%. It can have a higher relative humidity at a lower temperature. The average maximum humidity of the wettest month is 90%, and the average minimum temperature of the month is + 25 ℃, taking into account the condensation on the product surface due to temperature change;
- Place without violent vibration and impact vibration;
- A place free from rain and snow;
- The voltage waveform is similar to the sine wave.
Characteristics
Thermal stability
Advanced product design, strict control of the product’s seating position, and the temperature rise of the hottest spot. Copper wire is used for coil and lead wire, and the current density is low.
Overload capacity
The control transformer has strong overload capacity and overvoltage capacity. The product design and manufacturing fully consider the load characteristics and meet the overload requirements from the aspects of temperature rise, insulation performance, and accessories selection.
Energy saving
Obvious power saving effect and low noise (< 65dB).
Compact
Simple structure, beautiful appearance.
Application
Control transformer usually used in machine tools or mechanical equipment as electrical control lighting and indicator power supply. It is convenient to obtain suitable voltage; secondary grounding is strictly prohibited. Anti-interference.